B3 |
HV switches with fixed on-time, high di/dt, ultra fast, MOSFET |
● HV switch with extremely fast turn-on rise time ● True gate control (no avalanche technique) for highest reliability over a wide range of operating temperatures and load conditions ● Very low impedance ● Very EMC tolerant ● Available with on-time options from 5 ns to 1 μs ● Designed for attachment on printed circuit boards (PCB) |
Product Code: The model number contains coded information about voltage, current and turn-on behavior. The first digits stand for the voltage in kV, the last digit before the dash indicates the turn-on behavior (0 = fixed on-time, 1 = variable on-time). The digits after the dash indicate the current in Amperes x10. Special features are coded by the letters after a second dash. Example HTS 30-06-UF: HTS = HV Transistor Switch, 3 = 3 kV, 0 = fixed on-time, 06 = 60 Ampere, UF = Ultra Fast |
Model [sorted by |
Description / Comment |
Drawing (PDF) |
Dimensions |
Voltage |
Pk. Current |
On-Resist. |
On-Time |
|
HTS 30-06-UF | ● | request |
80 x 38 x 25
|
3.6
|
60
|
3.6
|
120
|
|
HTS 30-08-UF | ● | request |
80 x 38 x 25
|
3
|
80
|
2.5
|
120
|
|
HTS 50-08-UF | ● | request |
89 x 64 x 31
|
5
|
80
|
4
|
200
|
|
HTS 50-12-UF | ● | Option OT-5n not available | request |
89 x 64 x 31
|
5
|
120
|
3
|
200
|
HTS 80-12-UF | ● | Option OT-5n not available |
122 x 64 x 31
|
8
|
120
|
4.5
|
200
|
|
HTS 80-20-UF | ● | Option OT-5n and OT-10n not available |
122 x 89 x 31
|
8
|
200
|
2.7
|
200
|
|
HTS 100-20-UF | ● | Option OT-5n and OT-10n not available |
150 x 89 x 31
|
10
|
200
|
3.4
|
200
|
|
HTS 120-15-UF | ● | Option OT-5n and OT-10n not available | request |
153 x 89 x 31
|
12
|
150
|
4.8
|
200
|
Options (1) |
|
|
|
HFB |
High Frequency Burst: Improved burst capability of driver by means of external buffer capacitors. Recommended if more than 10 pulses with less than 10 μs spacing are generated. |
HFS |
High Frequency Switching: External supply of auxiliary driver voltage (50-350 VDC according to type). Necessary if the specified “Maximum Operating Frequency” shall be exceeded. (2) |
LP |
Low Pass: Low pass filter at the control input. Propagation delay time will be increased by ~50 ns. Jitter + 500 ps. Improved noise immunity and less critical wiring in high speed applications. (3) |
OT-5n |
On-Time Reduction: On-Time reduced to 5 ns |
OT-10n |
On-Time Reduction: On-Time reduced to 10 ns |
OT-20n |
On-Time Reduction: On-Time reduced to 20 ns |
OT-P |
Programmable On-Time: On-Time adjustable in certain limits by means of external programming resistors. (2) |
OT-C |
Customized On-Time: On-Time according to customer’s specifications. Any value between 20 ns and 1 μs. (2) |
MIN-PS |
Minimum Pulse Spacing: Individually increased Recovery Time to ensure a minimum HV pulse spacing indepently of control pulse spacing. For safety relevant circuits. |
ST |
Stage Tapping: Connectors at the individual stages of stack in order to utilize single power semiconductors. To achieve fast rise times also at very low operating voltages (<0.01xVo). |
LNC |
Low Natural Capacitance: CN reduced by approximately 30%. To minimize capacitive power losses in applications with high switching frequency and high switching voltage.. |
LL |
Low Leakage Current: Off-state current reduced to less than 10% of the specified value. Not available in connection with the cooling fin options and for switches of the UF series. |
ISO-25 |
25 kV Isolation: Isolation Voltage increased to 25 kVDC. Housing dimensions may change for some models. |
ISO-40 |
40 kV Isolation: Isolation Voltage increased to 40 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
ISO-80 |
80 kV Isolation: Isolation Voltage increased to 80 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
I-PC |
Integrated Part Components: Integration of small part components according to customer’s specifications (e.g. buffer capacitors, snubbers, damping resistors, diodes, opto couplers). (2) |
I-FWD |
Integrated Free-Wheeling Diode: Built-in parallel diode with short recovery time. In connection with inductive load only. |
I-FWDN |
Integrated Free-Wheeling Diode Network: Built-in parallel diode plus serial blocking diode with short recovery time. In connection with inductive load only. |
SEP-C | Separate Control Unit. Control unit with LED indicators in a separate housing (dim. 79x38x17 mm). Linkage cable (<1m) with plug. Control unit with soldering pins or pigtails |
FOI-C |
Fibre Optics Input / Control: Additional optical control input to trigger the switch with a fibre-optical signal (only in combination with option SEP-C) (2) |
FOO-F |
Fibre Optics Output / Fault: Additional optical output to read-out the failure condition of the switch by means of a fibre-optical signal (only in combination with option SEP-C) (2) |
I-PC |
Integrated Part Components: Integration of small part components according to customer’s specifications (e.g. buffer capacitors, snubbers, damping resistors, diodes, opto couplers). (2) |
LS-C | LEMO socket for Control Connection. Input Z=100Ω. An assembled linkage cable (1m/3ft) with two plugs and one socket is included in supply. Improved noise immunity. (3) |
PT-C |
Pigtail for Control Connection: Flexible leads (l=75 mm) with PCB connector. This option is only relevant for switching modules with pins. Recommended for modules with options CF & GCF. |
PIN-C |
Pins for Control Connection: Gold plated pins for printed circuit board designs (special sockets available). This option is only relevant for switching modules which have pigtails as standard. |
PT-HV |
Pigtails for HV Connection: Flexible leads with cable lugs. For increased creepage. PT-HV is standard for all types with >25 kV switching voltage. Not recommended in extremely fast circuits. |
ST-HV |
Screw Terminals for HV Connection: Threaded inserts at the bottom of module (if not standard). For PCB design. Operation above 25 kV requires liquid insulation (Galden®/Oil) or potting. |
UL94 |
Flame Retardant Casting Resin: Casting resin according to UL-94-VO. Minimum order quantity required. (2) |
FH | Flange Housing: Plastic flange housing for isolated attachment on conductive surfaces. Ideal if the switch is not intended for printed circuit boards. Option PT-HV is suggested. |
TH |
Tubular Housing: Tubular instead of rectangular housing. Adaption to specific ambient conditions or in case of difficult assembly situations. ‚ |
FC |
Flat Case: Height of standard plastic housings reduced to 19 mm or less. Not in combination with cooling options CF, GCF and DLC. |
ITC |
Increased Thermal Conductivity: Special moulding process to increase the thermal conductivity of the module. Pd(max) will be increased by approx. 20-30%. (2) |
CF |
Copper Cooling Fins d = 0.5 mm: Fin height 35 mm. Nickel plated. For air cooling with forced or natural convection as well as for liquid cooling with non-conductive coolants. |
CF-1 |
Copper Cooling Fins d = 1 mm: Fin thickness 1.0 mm instead of 0.5 mm. The Max. Power Dissipation Pd(max) will be increased by ~80 %. For air or liquid cooling (e.g. Galden® or oil). |
CF-X2 |
Copper Cooling Fins "XL": Fin area enlarged by factor 2. Recommended for natural air convection. No significant cooling power improvement in connection with forced air or liquid cooling. |
CF-X3 |
Copper Cooling Fins "XXL": Fin area enlarged by factor 3. Recommended for natural air convection. No significant cooling power improvement in connection with forced air or liquid cooling. |
CF-CS |
Copper Cooling Fins with customized shape: Individual shape to meet specific OEM requirements. (2) Can be combined with options CF-1, CF-D and CF-S for increased cooling power. |
CF-LC |
Copper Cooling Fins for liquid cooling: Double fins, nickel plated copper, height 20 mm. For the immersion in oil tanks etc. Forced convection recommended. Combinable with opt. CF-S. |
CF-D |
Double Copper Cooling Fins: Approx. 100% more cooling power, approx. 2mm spacing between fins, forced convection recommended. Combinable with opt. CF-S, CF-X2, CF-X3 and CF-CS. |
CF-S |
Copper Cooling Fins: Semiconductors soldered on fins. Approx. 30% to 100% more cooling power (type depending). Combinable with options CF-D, CF-X2, CF-X3 and CF-CS. |
CF-GRA |
Non-isolated Cooling Fins made of graphite: Very light weight compared to copper at similar heat transfer, but reduced heat capacity. 0.5 or 1 mm thickness, height 35 mm. |
CF-CER |
Isolated Cooling Fins made of ceramics: Heat transfer properties similar to alumina. Forced convection recommended due to 2 mm spacing between fins. Height 35 mm. |
CCS |
Ceramic Cooling Surface: Top side of switching module made of ceramics. Heat transfer properties similar to alumina. Max. 20 kVDC isolation. Forced convection recommended. |
CCF |
Ceramic Cooling Flange: Bottom side of switching module made of a plano grinded ceramic plate. Integrated metal frame for uniform and safe contact pressure. Max. 40 kVDC isolation. |
C-DR |
Cooling for Driver: Extra cooling for the driver and control electronics. Recommended in combination with option HFS at higher switching frequencies. (2) |
GCF |
Grounded Cooling Flange: Nickel-plated copper flange for High Power applications. Max. isolation voltage 40kV. Increased coupling capacitance Cc. |
GCF-X2 |
Grounded Cooling Flange, Max. Continuous Power Dissipation increased by x2: Thermal resistance “Switch to Flange” reduced for twice the power capability. (2) |
ILC |
Indirect Liquid Cooling: Liquid cooling for all kind of conductive coolants including mains water. Internal heat exchanger made of ceramics. For medium power applications. |
DLC |
Direct Liquid Cooling: Internal cooling channels arround the power semiconductors. The most efficient cooling solution especally for high frequency applications. For non-conductive coolants only. |
HI-REL |
High Reliability / MIL Versions: Available on request. (2) |
|
|
(1) New option code: Data
sheets may differ from this coding system (especially older ones) and
do not indicate all possible options as per above table. (2) Please
consult factory for detailed information. |
|
|
|
|
||